If you live in Round Rock, you may already have experienced the brutal summers of the city. The temperature varies from 73°F to 98°F. The summer lasts from May to October. Similarly, winters go on for 2-3 months with an average low temperature of 38°F.Â
This means that your HVAC system in Round Rock faces brutal heat and occasional freezing cold.Â
In order to survive the seasons, you need to have a system that provides the right efficiency level for the local climate. Read to know all about SEER ratings and how they maximize efficiency and minimize air conditioner repair in Round Rock TX.Â
SEER is an obsolete term. SEER2 has now replaced SEER to improve the accuracy and consistency of energy efficiency ratings for air conditioners and heat pumps.Â
A SEER rating is defined as the Seasonal Energy Efficiency Ratio. It helps measure the cooling efficiency of an air conditioner. A higher rating indicates an energy efficient system.Â
Both SEER and SEER2 represent energy efficiency but relate to varying sets of guidelines and regulations.Â
SEER2 replaced SEER because the former includes more stringent testing methods. These methods account for real-world conditions, such as ductwork losses and airflow resistance. These things were not fully considered in the original SEER testing.Â
SEER2 ensures a more accurate representation of a unit’s energy efficiency. This encourages manufacturers to produce more energy-efficient systems. This helps consumers make more informed choices.Â
What’s more, SEER2 aligns with the updated Department of Energy regulations.
The humidity in Round Rock, Texas keeps fluctuating. So, when opting for an air conditioner installation Round Rock TX, you should consider more than one metric.Â
According to the Department of Energy, for areas in Texas, 14.3 SEER2 is the minimum allowable cooling efficiency for residential, air-source, and split-system heat pumps.Â
Here are the SEER2 requirements for Split System Air Conditioners.Â
System Type | SEER2 Rating |
Split System ACs (AC < 45K Btu/h) | 14.3 SEER2 11.7 EER2** |
Split System ACs (AC ≥ 45K Btu/h) | 13.8 SEER2 11.2 EER2** |
Split System Heat Pumps also have their standards.Â
System Type | New SEER2 and HSPF2 |
Split System HPs | 14.3 SEER2 7.5 HSPF2 |
Here is the SEER2 rating for a single packaged unit.Â
System Type | New SEER2 and HSPF2 |
Packaged ACs, Heat Pumps, Gas Electrics, and Dual-Fuel HPs | 13.4 SEER2 6.7 HSPF2 |
SEER2 = Cooling Output ÷ Electricity Used over an entire season.Â
Here is an example.Â
Imagine having around 24,000 BTUs of cold air in your rooms while the meter reads 1,000 watt-hours. In that case, the SEER2 is 24.Â
A higher SEER2 means that your AC removes more heat for the same power. Besides, higher efficiency results in cost savings on your monthly cooling bills.Â
Use this worksheet to estimate your potential savings. We’ve pre-filled the Round Rock Climate Constants (our average electricity rates and estimated cooling hours) to keep it accurate for our local 100°F+ summers.
First, identify how much "cooling power" your home needs based on its size.
Home Square Footage | Estimated Tonnage | Total BTUs |
1,000 – 1,200 | 2.0 Tons | 24,000 BTU |
1,300 – 1,600 | 2.5 Tons | 30,000 BTU |
1,700 – 2,100 | 3.0 Tons | 36,000 BTU |
2,200 – 2,600 | 3.5 Tons | 42,000 BTU |
2,700 – 3,200 | 4.0 Tons | 48,000 BTU |
3,300 – 4,000 | 5.0 Tons | 60,000 BTU |
Plug your numbers into the empty column below to see your estimated annual cooling cost.
Variable | Description | Your Home's Value |
(A) Tonnage | From the table in Step 1 | __ |
(B) Cooling Hours | Central Texas Avg: 2,600 hours | 2,600 |
(C) Electricity Rate | Round Rock Average: $0.14 (Oncor Service Area) | $0.14 |
(D) Target SEER2 | The rating of your new unit (e.g., 14.3 or 18) | __ |
To find your estimated annual cost to run the unit, use this formula: ((A × 12,000 × B) / D / 1,000) × C = Annual Cooling Cost
Example: A 1,500 sq. ft. home (2.5 Tons) with a standard 14.3 SEER2 unit: ((2.5 × 12,000 × 2,600) / 14.3 / 1,000) × 0.14 = $763.63 per year
*1 Ton of cooling capacity = 12,000 BTUs per hour.
When you multiply your tonnage (Variable A) by 12,000, you are converting the size of your AC unit into the total amount of heat it can remove from your home in one hour.
If you are deciding whether to pay more for a 17 SEER2 vs. a 14.3 SEER2, use this table to see the estimated 10-year savings.
Upgrade Comparison | Est. Annual Savings | 10-Year Total Savings |
Old 10 SEER → 14.3 SEER2 | ~35% Savings | $3,000 – $5,000 |
Old 10 SEER → 18.0 SEER2 | ~50% Savings | $5,500 – $8,000 |
14.3 SEER2 → 18.0 SEER2 | ~20% Savings | $1,500 – $2,500 |
Home size significantly impacts the "break-even" point for high-efficiency equipment. Larger homes demand systems with high SEER2 ratings.
Suppose you have a home in an older neighborhood, around ~1,200 sq. ft.
In that case, a system size of 2 Tons (24,000 BTU) with a recommended rating of 14.3 to 15.2 SEER2 may seem suitable.Â
This is because older homes often have less attic insulation.
The system can help you focus on sealing the attic of the home.
Here is another example of a suburban family home. This one is around 2,400 sq. ft.
In that case, it may need a system size of 4 Tons (48,000 BTU) with a 16 to 17.5 SEER2.
Such family homes have large south-facing windows, common in newer neighborhoods.
A 16 to 17.5 SEER2 works as a sweet spot. At this level, you can get two-stage cooling to beat Round Rock's high humidity levels.Â
On the other hand, a luxury estate with an area of 3,800+ sq. ft. may require a 5-ton or dual system. That’s because such homes have high ceilings with expansive open floor plans.
In this case, the recommended SEER2 is 18+.Â
Such homes have a massive cooling load. A variable-speed system helps keep the temperature under control while providing comfort and noise reduction.Â
Here is a rule of thumb to consider.Â
When comparing quotes from local contractors for air conditioning repair Round Rock Tx or installation, ensure you check the following:
If you need professional assistance in buying and installing the right air conditioner for your home, choose Grande Air. With our knowledge and experience, we will make sure to help you choose the right HVAC system for your home. Besides, we also offer competent air conditioner repair Round Rock TX services so you can beat the heat this summer.Â
Contact Grande Air today at (512) 677-4424!Â
Efficiency also depends on attic insulation and ductwork sealing, which prevent your cooled air from escaping before it reaches the room.
Most high-efficiency units require a specific communicating thermostat to properly manage the advanced compressor speeds that generate your savings.
SEER2 ratings are only valid when the indoor and outdoor components are a factory-matched pair; mixing old and new parts often voids the efficiency rating.
Variable-speed units are designed to run for longer periods at lower power to maintain a steady temperature rather than providing a single, heavy blast of cold air.
Energy-efficient upgrades are highly attractive to modern buyers in Texas markets, as they represent lower long-term ownership costs and a smaller carbon footprint.